Novaris protection for both Power and Signal is provided in a compact and economical DIN compliant package. They are ideal for security and CCTV camera protection.
Novaris protection for both Power and Signal is provided in a compact and economical DIN compliant package. They are ideal for security and CCTV camera protection.
Application Notes Download
| Specifications | SFD1-6-3-30-C | SFD1-6-10-275-C | ||
|---|---|---|---|---|
| Power maximum continuous voltage (DC) | U꜀ | 40V | 380V | |
| Power maximum continuous voltage (AC) | U꜀ | 30V | 275V | |
| Power maximum discharge current (8/20μs) | Iₘₐₓ | 3kA per line | 10 kA per line | |
| Power impulse durability | C2 8/20μs 2kA | |||
| Power maximum load current | IL | 6 A | ||
| Power voltage protection level @ 3 kA (8/20 μs) | Uₚ | 100V | 700V | |
| Signal maximum continuous voltage (DC) | U꜀ | 8.2VDC | ||
| Signal maximum discharge current (8/20μs) | 20kA | |||
| Signal voltage protection level @ 1 kV/μs | Uₚ | 14V | ||
| Dimensions | 📐 | W 18mm x H 115mm x D 69mm | ||
| Weight | 📦 | 160g | ||
| Product Datasheet | SFD1-6-3-30-C | SFD1-6-10-275-C | ||